root / base / usr / src / cmd / fm / dicts / DISK.po
DISK.po Plain Text 124 lines 4.9 KB
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
#
# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
# Copyright 2016 Nexenta Systems, Inc.  All rights reserved.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: DISK-8000-0X
# keys: fault.io.disk.predictive-failure
#
msgid "DISK-8000-0X.type"
msgstr "Fault"
msgid "DISK-8000-0X.severity"
msgstr "Major"
msgid "DISK-8000-0X.description"
msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
msgid "DISK-8000-0X.response"
msgstr "None.\n"
msgid "DISK-8000-0X.impact"
msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
msgid "DISK-8000-0X.action"
msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
#
# code: DISK-8000-12
# keys: fault.io.disk.over-temperature
#
msgid "DISK-8000-12.type"
msgstr "Fault"
msgid "DISK-8000-12.severity"
msgstr "Major"
msgid "DISK-8000-12.description"
msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
msgid "DISK-8000-12.response"
msgstr "None.\n"
msgid "DISK-8000-12.impact"
msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
msgid "DISK-8000-12.action"
msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
#
# code: DISK-8000-2J
# keys: fault.io.disk.self-test-failure
#
msgid "DISK-8000-2J.type"
msgstr "Fault"
msgid "DISK-8000-2J.severity"
msgstr "Critical"
msgid "DISK-8000-2J.description"
msgstr "One or more disk self tests failed.\n  Refer to %s for more information."
msgid "DISK-8000-2J.response"
msgstr "None.\n"
msgid "DISK-8000-2J.impact"
msgstr "The disk has failed.\n"
msgid "DISK-8000-2J.action"
msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
#
# code: DISK-8000-3E
# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
#
msgid "DISK-8000-3E.type"
msgstr "Fault"
msgid "DISK-8000-3E.severity"
msgstr "Critical"
msgid "DISK-8000-3E.description"
msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
msgid "DISK-8000-3E.response"
msgstr "The device may be offlined or degraded.\n"
msgid "DISK-8000-3E.impact"
msgstr "The device has failed. The service may have been lost or degraded.\n"
msgid "DISK-8000-3E.action"
msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
#
# code: DISK-8000-4Q
# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
#
msgid "DISK-8000-4Q.type"
msgstr "Fault"
msgid "DISK-8000-4Q.severity"
msgstr "Critical"
msgid "DISK-8000-4Q.description"
msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
msgid "DISK-8000-4Q.response"
msgstr "The device may be offlined or degraded.\n"
msgid "DISK-8000-4Q.impact"
msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
msgid "DISK-8000-4Q.action"
msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
#
# code: DISK-8000-8D
# keys: fault.io.disk.ssm-wearout
#
msgid "DISK-8000-8D.type"
msgstr "Fault"
msgid "DISK-8000-8D.severity"
msgstr "Major"
msgid "DISK-8000-8D.description"
msgstr "A solid state media device is nearing end of life as projected by the manufacturer."
msgid "DISK-8000-8D.response"
msgstr "None."
msgid "DISK-8000-8D.impact"
msgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
msgid "DISK-8000-8D.action"
msgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."